  • Designed to operate in colder climates... aslow as -40 F (-40 C)
  • Brief Specs
  • FUEL Diesel
  • OUTPUT (BTU/H) 301,000
  • FUEL CAPACITY 150 US GAL
  • ONBOARD HOSE MAX 3,000 ft
  • Ground Thaw Coverage with On Board Hose: 4500 sq ft
  • Ground Cure Coverage with On Board Hose: 6000 sq ft
  • Additional Hose Cost: $0.50 per linear foot.
  • Key Features
  • Patented Flow Reverser Eliminates hot and cold zones in the thaw pattern
  • Reduces time & fuel costs by up to 50%
  • Consistent curing temperatures across the entire slab the whole slab cures faster at the same rate
  • Patented Combustion Environment Control System
  • Preheat s the fuel and air used for combustion
  • No need to bring the greenthaw in to a heated shop before it goes out on the job. The preheater allows the unit to start & run even in sub 40 degree conditions
  • Industry leading multi-loop ground thaw set-up for job site flexibility and optimum fluid circulation & heat transfer
  • Manifold System allows for fan coils or heat exchangers to plug in for space heating or fluid heating
  • Detailed Specs:
  • Trailer dimensions: 188 long x 76 wide x 96 tall
  • Dry Weight: 5950 lbs
  • Burner: single stage
  • Fuel: diesel fuel/#1
  • Input capacity: 301,000 BTUH, 87.2 KW
  • Output capacity: 255,850 BTUH, 71.5 KW
  • Consumption (100% run time): 2.15 US GPH, 8.14 LPH
  • Fuel capacity: 150 US GAL
  • Maximum thawing capacity: 6,000 sq.ft
  • Heating capacity - area: 433,154 cu.ft.
  • Heat transfer fluid (HTF) circulation system
  • HTF: non-toxic propylene glycol / water mix
  • Maximum operating temp: 195 F
  • Operating pressure: 35 PSI
  • Flow: 965 GPH
  • HTF flow reversing system: Adjustable cycle time
  • Circulation loop length -max: 1,000 ft.
  • Circulation loop length -min: 500 ft.
  • Climate control system
  • Fuel heater: maintains set fuel temperature
  • Combustion air heater: maintains set combustion air temperature
  • Control & monitoring
  • Pump & temperature controls
  • Full gauge panel showing circulation fluid temperatures & pressures, fuel pressures
  • Multi-light system operation feature for easy system troubleshooting
  • External operating light
  • Powered hose reel
  • Controls: forward / reverse
  • Foot switch activation
  • Onboard hose - max: 3,000 ft.
  • Manifold: Detachable, 6-port
  • Generator: Kubota GL7000 7KW Diesel