  • Type ...................................- Staged output, electric spark ignition
  • Temperature Range...........- 120°F to 200°F (49°C to 93°C)
  • Fuels specs
  • ...Natural gas fired
  • .......*Input capacity............- 1,233,000 BTU/H
  • .......*Output capacity .........- 1,023,390 BTU/H
  • .......Gas pressure range ...- 6” to 14” W.C.
  • .......Manifold gas pressure - 3.5” to 4” W.C.
  • .......Consumption - max ....- 1,233 CU.FT/H (34.9 CU.M/H)
  • Propane fired
  • .......*Input capacity............- 1,134,360 BTU/H
  • .......*Output capacity .........- 941,544 BTU/H
  • .......Gas pressure..............- 11” W.C.
  • .......Manifold gas pressure - 10” to 11” W.C.
  • .......Consumption - max. ...- 12.4 US GAL/H (46.9 L/H)
  • Control & monitoring..........- Full gauge panel monitoring
  • circulation fluid temperatures &
  • pressures, fuel pressures
  • ...........................................- 11-light system operation feature for
  • easy system troubleshooting.
  • Weight................................- 1,815 LBS. (823 KG)
  • Electrical ............................- 115/230 V, single phase, 60 Hz,
  • 30 Amps
  • Loading - standard.............- Forklift pockets on all four sides
  • Module fluid circulation system
  • ...Basic features.................- Atmospherically vented low pressure
  • system, adjustable fluid
  • temperature control, auto pressure
  • by-pass for pump protection and
  • variable flow demands, auto
  • temperature bypass for heat
  • exchanger protection.
  • ...Heat transfer fluid (HTF) - Non-toxic propylene glycol / water
  • mixture, freeze protected
  • ...Primary lines & couplers - 2' fluid circulation lines, 2” ball
  • valves, 2" Kamlock quick-couplers
  • ...Circulation pump ............- 2 HP, 80 GPM (364 LPM) @ 30
  • P.S.I.
  • ...Lock-out..........................- Locks out primary “supply” & “return”
  • fluid circulation valves and control
  • panel
  • Optional
  • ...Transport trailer
  • ...Skyhook frame ...............- Steel frame with four corner lifting
  • eyelets, weld attach to water heater
  • module base
  • ...Gas conversion ..............- Propane or natural gas burner trays
  • and gas trains